245 research outputs found
Topical delivery of hexamidine
Hexamidine diisethionate (HEX D) has been used for its biocidal actions in topical preparations since the 1950s. Recent data also suggest that it plays a beneficial role in skin homeostasis. To date, the extent to which this compound penetrates the epidermis has not been reported nor how its topical delivery may be modulated. In the present work we set out to characterise the interaction of HEX D with the skin and to develop a range of simple formulations for topical targeting of the active. A further objective was to compare the skin penetration of HEX D with its corresponding dihydrochloride salt (HEX H) as the latter has more favourable physicochemical properties for skin uptake. Candidate vehicles were evaluated by in vitro Franz cell permeation studies using porcine skin. Initially, neat solvents were investigated and subsequently binary systems were examined. The solvents and chemical penetration enhancers investigated included glycerol, dimethyl isosorbide (DMI), isopropyl alcohol (IPA), 1,2-pentanol (1,2-PENT), polyethylene glycol (PEG) 200, propylene glycol (PG), propylene glycol monolaurate (PGML) and Transcutol®P (TC). Of a total of 30 binary solvent systems evaluated only 10 delivered higher amounts of active into the skin compared with the neat solvents. In terms of topical efficacy, formulations containing PGML far surpassed all other solvents or binary combinations. More than 70% of HEX H was extracted from the skin following application in PG:PGML (50:50). Interestingly, the same vehicle effectively promoted skin penetration of HEX D but demonstrated significantly lower uptake into and through the skin (30%). The findings confirm the unpredictable nature of excipients on delivery of actives with reference to skin even where there are minor differences in molecular structures. We also believe that they underline the ongoing necessity for fundamental studies on the interaction of topical excipients with the skin
Permutation tests following restricted randomization procedures
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/28639/1/0000453.pd
Randomization in clinical trials: Conclusions and recommendations
The statistical properties of simple (complete) randomization, permuted-block (or simply blocked) randomization, and the urn adaptive biased-coin randomization are summarized. These procedures are contrasted to covariate adaptive procedures such as minimization and to response adaptive procedures such as the play-the-winner rule. General recommendations are offered regarding the use of complete, permuted-block, or urn randomization. In a large double-masked trial, any of these procedures may be acceptable. For a given trial, the relative merits of each procedure should be carefully weighed in relation to the characteristics of the trial. Important considerations are the size of the trial, overall as well as within the smallest subgroup to be employed in a subgroup-specific analysis, whether or not the trial is to be masked, and the resources needed to perform the proper randomization-based permutational analysis.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/27041/1/0000029.pd
Graphical Elicitation of a Prior Distribution for a Clinical Trial
1 online resource (PDF, 27 pages
Validation of a new In Vitro Sun Protection Factor (SPF) method to include a wide range of sunscreen product emulsion types
In 2017, Cosmetics Europe performed a double-blinded ring test of 24 emulsion-type sunscreen products, across 3 in vivo test laboratories and 3 in vitro test laboratories, using a new candidate in vitro SPF test method. Based on the results of this work, an article was published showing how data derived from a new lead candidate method conform to new International Standards (ISO) acceptance criteria for alternative SPF test methods (Any alternative method should consider the matrix effect and if required, specify the matrix applicability of the method; Criterion 1a: Systematic differences between methods should be negligible: 95% of all individual results of an alternative method are within the range of ±2× reproducibility standard deviation of the in vivo method, that is overall bias must be below 0.5× reproducibility standard deviation of the in vivo method; Criterion 1b: Measurement uncertainty of an alternative method should be below the measurement uncertainty of the in vivo method. Candidate method predicted values must fall within the full 'funnel' (SPF 6-50+) limits proposed by Cosmetics Europe (derived from the same minimum test design, that is using the ISO24444 Method to measure at least 24 products across at least 3 laboratories using at least 5 test subjects/laboratory, in a blinded fashion).). Of the 24 sunscreen products tested, the majority of emulsions were of the oil-in-water (O/W) type, whereas only one was water-in-oil (W/O) and there were no products with a mineral-only sun filter system. In order to confirm the scope of this method, therefore, a new study was conducted that included 73 W/O (12 mineral + organic, 44 mineral only and 17 organic only) and 3 O/W mineral-only, emulsion-type sunscreen products (a total of 76 new sunscreen products). When combined with the previous 24 products (tested in 3 different laboratories), this yielded a new data set comprising a total of 100 emulsion-type sunscreen products, with SPF values ranging from 6 to 50+ (with a total of 148 data points). These products were tested using the double-plate in vitro SPF test method and compared with the ISO TC217/WG7 acceptance criteria for alternative SPF test methods. Over 95% of paired in vitro: in vivo SPF values lay within the upper and lower limits of the ISO acceptance criteria funnel, with no bias. This new in vitro SPF test method, therefore, meets the minimum requirements for an alternative SPF test method to ISO24444:2010, for emulsion-type sunscreen products (which make up the majority of marketed sunscreen products)
Recommended from our members
Discontinuation of Prophylaxis against Mycobacterium avium Complex Disease in HIV-Infected Patients Who Have a Response to Antiretroviral Therapy
BACKGROUND
Several agents are effective in preventing Mycobacterium avium complex disease in patients with advanced human immunodeficiency virus (HIV) infection. However, there is uncertainty about whether prophylaxis should be continued in patients whose CD4+ cell counts have increased substantially with antiviral therapy.
METHODS
We conducted a multicenter, double-blind, randomized trial of treatment with azithromycin (1200 mg weekly) as compared with placebo in HIV-infected patients whose CD4+ cell counts had increased from less than 50 to more than 100 per cubic millimeter in response to antiretroviral therapy. The primary end point was M. avium complex disease or bacterial pneumonia.
RESULTS
A total of 520 patients entered the study; the median CD4+ cell count at entry was 230 per cubic millimeter. In 48 percent of the patients, the HIV RNA value was below the level of quantification. The median prior nadir CD4+ cell count was 23 per cubic millimeter, and 65 percent of the patients had had an acquired immunodeficiency syndrome-defining illness. During follow-up over a median period of 12 months, there were no episodes of confirmed M. avium complex disease in either group (95 percent confidence interval for the rate of disease in each group, 0 to 1.5 episodes per 100 person-years). Three patients in the azithromycin group (1.2 percent) and five in the placebo group (1.9 percent) had bacterial pneumonia (relative risk in the azithromycin group, 0.60; 95 percent confidence interval, 0.14 to 2.50; P=0.48). Neither the rate of progression of HIV disease nor the mortality rate differed significantly between the two groups. Adverse effects led to discontinuation of the study drug in 19 patients assigned to receive azithromycin (7.4 percent) and in 3 assigned to receive placebo (1.1 percent; relative risk, 6.6; P=0.002).
CONCLUSIONS
Azithromycin prophylaxis can safely be withheld in HIV-infected patients whose CD4+ cell counts have increased to more than 100 cells per cubic millimeter in response to antiretroviral therapy
- …